F-gas rules in Slovakia and Czechia in 2027 – an overview for technicians
Roman Oškrobaný · · 5 min read
Since March 2024 a new EU F-gas Regulation applies, (EU) 2024/573. It applies directly in every country, but national laws are slow to catch up: the Slovak act hasn't changed yet, the Czech one is being amended right now. This post sets out what applies in 2027 to a technician who installs and services air conditioners and heat pumps – first across the EU, then in Slovakia and in Czechia.
What applies across the EU
A1 and A2 certificates. A2 covers only charges under 3 kg (hermetically sealed under 6 kg); everything else needs a technician with A1. The old categories I to IV count as A1, A2, D and E once the holder has refreshed their knowledge.
A refresher at least every 7 years – from 12 March 2027. Holders of older certificates need their first one by 12 March 2029.
Installation includes joining a pre-charged split on site – it needs a certified technician and a certified company.
The F-gas label: on equipment that gets refrigerant added on site, the installer writes in the added amount and the total charge before start-up. How to work them out is in the post The F-gas label at commissioning.
Leak checks and the equipment record from 5 t CO₂ equivalent: for R32 from 7.41 kg, for R410A from 2.40 kg.
A leak check right after installation is no longer required: Regulation 1516/2007 was repealed from 23 July 2026 without a replacement.
Servicing: since 1 January 2026 air conditioners and heat pumps may not be serviced with gases of GWP 2,500 or more. R32 and R410A are both below that limit.
Disposable cylinders for F-gases may not be imported, sold or used.
Bans on new equipment
From
No longer allowed on the market
1 Jan 2025
single splits under 3 kg with GWP 750 or more (new R410A splits)
1 Jan 2027
split air-to-water heat pumps up to 12 kW with GWP 150 or more; self-contained (monoblock) units up to 12 kW with GWP 150 or more
1 Jan 2029
air-to-air splits up to 12 kW with GWP 150 or more (new R32 splits)
1 Jan 2035
splits up to 12 kW with any F-gas
Equipment placed on the market before a ban date may still be installed. Most bans have an exception where on-site safety rules don't allow the lower-GWP option.
Less refrigerant on the market. The amount of HFCs that may be placed on the EU market falls in steps: about 42.9 million t CO₂-eq a year in 2025–2026, about 21.7 million in 2027–2029 – roughly half – and zero from 2050. Expect both R32 and R410A to get scarcer and dearer.
Slovakia
Act 286/2009 Coll. and Decree 314/2009 Coll. still apply, in their 2022 and 2017 versions. No new act for Regulation 2024/573 had been published by November 2026, and the act still speaks of the old categories I to IV.
The technician's certificate (osvedčenie o odborných znalostiach) is valid for 5 years. The company certificate (certifikát o odbornej spôsobilosti), also for a sole trader, is valid for 1 year; to renew it the company declares that it has the prescribed tools and keeps leak-check records electronically, and hands in last year's report.
Records of how F-gases and equipment were handled are kept for at least 5 years. The report goes to the certification body every year by 31 January.
The sticker after a leak check: after each check the company labels the equipment – the month and year of this check and of the next one, the technician's name and certificate number, the company and its certificate number.
The register of operators for equipment of 5 t CO₂-eq or more is in the act, but the ministry postponed it indefinitely in a notice of 10 January 2024.
Supervision and fines: the Slovak Environmental Inspectorate (SIŽP). Fines from €300 to €7,000 (for example a missing label or report), from €300 to €34,000 (records, leak checks, a leak not repaired) and from €5,000 to €99,600 (work without a certificate, selling banned equipment).
The evaluation body is SZ CHKT in Šamorín; certificates are issued by the certification body for refrigeration and air-conditioning (Certifikačný orgán pre chladiacu a klimatizačnú techniku).
Czechia
Act 73/2012 Coll.: only a certified person may install. A company is certified by showing an employee's certificate and a declaration; the ministry keeps the register.
A pre-charged split may be sold to an end customer only with a written contract that names the unit's serial number and says a certified person will install it. The seller keeps it for 5 years.
Records under Decree 243/2023 Coll. are kept in Czech, on paper or electronically. An electronic record must name who made each entry, is corrected only by a new entry (the original stays), must be backed up and must be printable for an inspection.
The amendment (parliamentary print 14): the Chamber of Deputies passed it on 14 October 2026; it has been in the Senate since 2 November 2026 (deadline 2 December 2026). The draft says certified persons will report through ISPOP by 31 March the refrigerant used when installing equipment charged on site, for servicing, and the refrigerant recovered. Whether and in what form it passes was not yet known on 18 November 2026.
What to get ready for 2027
Check your certificate: A1, or A2 (only under 3 kg)? If you hold an old certificate (category I to IV), plan your refresher – by 12 March 2029 at the latest.
Fill in the F-gas label at every installation: the added amount and the total charge, before start-up.
Keep records electronically, so that every entry names the technician and corrections are made by a new entry – that suits both the Slovak company certificate and the Czech decree.
Collect the numbers for the yearly report as you go: refrigerant charged into new equipment, added and recovered. In Slovakia by 31 January, in Czechia under the amendment probably by 31 March.
For air-to-water heat pumps up to 12 kW, from 2027 check that the unit was placed on the market before the ban.
In the ClimaToolkit app, Units and F-gas keeps a record for each unit – the charge, refrigerant added and recovered, who did the work, leak checks – and adds up the year's amounts for the report.
Try it in the app
Units and F-gasPart of Pro (during the beta, free for everyone who signs in)
Sources
Regulation (EU) 2024/573 on fluorinated greenhouse gases, Art. 4, 5, 7, 10, 11, 13, Annexes IV and VII. EUR-Lex (opens in a new tab)
E1 or EL01 on a Midea, Vivax or Inventor split: the indoor and outdoor units can't talk to each other. How to read the code, what usually causes it and what to measure, in order.
Half an hour? An hour? How long to evacuate a split, what the makers ask, why you need a micron gauge, and how the hold test tells moisture from a leak.