Inventor error codes
The app finds the right code table from the model number on the nameplate.
Open in the appInventor – Aria AR5 (AR5VI / AR5VO)
- Aria AR5
How to read codes on this unit
The display shows either the short code ( E1) or the long code (EL01), depending on the display board. Each code below lists its long form as the other spelling.Units without a display flash the lamps instead: the operation lamp blinks a number of times, and the timer lamp is off, on or flashing. Information inquiry (live readings): within 10 s press LED (Do Not Disturb) ×3, then SWING (Air Direction) ×3. LED shows the next item, SWING the previous one. Items: T1, T2, T2B, T3, T4, TP, TH, FT, Fr, IF, OF, LA, CT, ST. Frequencies of 100 Hz and more start with a letter: A0–A9= 100–109 Hz,b= 110s …F= 150s. LA is a hex value; ×2 = EXV opening in pulses. The manual does not say what the ST values mean.Outdoor board LEDs: some outdoor units have a red and a green LED on the board (see below). Garbled code: if the unit still obeys the remote, suspect the display board; if not, the indoor PCB.
Display codes
E0 Indoor EEPROM error E1 Indoor ↔ outdoor communication error E2 Zero-crossing detection error E3 Indoor fan speed out of range E4 Room sensor T1 open or short E5 Indoor coil sensor T2 open or short E7 Indoor PCB ↔ display board communication error EC Refrigerant leak detected F0 Current overload protection F1 Outdoor ambient sensor T4 open or short F2 Outdoor coil sensor T3 open or short F3 Discharge sensor TP open or short F6 Indoor coil outlet sensor T2B open or short F4 Outdoor EEPROM error F5 Outdoor fan speed out of range P0 IPM malfunction or IGBT over-current P1 Over- or under-voltage P2 IPM high temperature or high pressure P4 Inverter compressor drive error P6 Low-pressure protection P5 Indoor units in conflicting modes (multi split)
Inventor – Leon (LHUVI / LEUVI)
- Leon
How to read codes on this unit
The indoor display shows long 4-character codes only ( EL01). The lamps flash too, but the lamp column of the manual's table could not be read reliably, so no lamp patterns are given here.Engineer mode: with the unit on or in standby and the remote unlocked, hold ON/OFF + FAN for 7 s. ▲ / ▼ scroll through items 0–30: the current error code, then T1, T2, T3, T4, TP, FT, Fr, dL, Uo, Sn, Pr (×8), Lr (×8), ir (×8), Hu, TT, oT. Exit with ON/OFF + FAN for 2 s, or wait 60 s. Which item number belongs to which reading is not confirmed. Outdoor board LED: PC02, PC04, PC08, PC40 and PC03 are shown as 1, 3, 5, 6 and 7 flashes, but which code takes which count could not be read from the manual. Read the code on the indoor display instead. Not errors: dF(defrost),SC,CL(active clean),FP(8 °C heating),FC(forced cooling),AP(Wi-Fi AP mode),CP(remote switched off).
Display codes
EH00 Indoor EEPROM error EH0A Indoor EEPROM parameter error EL01 Indoor ↔ outdoor communication error EH02 Zero-crossing detection error EH03 Indoor fan speed out of control EC51 Outdoor EEPROM error EC52 Outdoor coil sensor T3 open or short EC53 Outdoor ambient sensor T4 open or short EC54 Discharge sensor TP open or short EC56 Indoor coil outlet sensor T2B open or short (multi split) EH60 Room sensor T1 open or short EH61 Indoor coil sensor T2 open or short EC07 Outdoor fan speed out of control EH0b Indoor PCB ↔ display board communication error EL0C Refrigerant leak detected PC00 IPM protection or IGBT over-current PC01 Over- or under-voltage (DC bus P–N out of range) PC02 Compressor-top or IPM over-temperature, or high pressure PC03 High- or low-pressure protection PC04 Inverter compressor drive error PC08 Current overload protection PC40 Main chip ↔ drive chip communication error -- Indoor units in conflicting modes (multi split) FH0P Wi-Fi AP mode requested, but no Wi-Fi module fitted
Engineer-mode codes
PC10 AC supply under-voltage PC11 DC bus over-voltage PC41 Compressor current detection error PC42 Compressor start error PC43 Compressor phase loss PC44 Compressor zero-speed protection PC46 Compressor speed out of control PC49 Compressor over-current PC0A Condenser high temperature PC06 Discharge temperature too high PC0L Outdoor ambient temperature too low FH0C Humidity sensor open or short PC0F PFC module error PC30 High-pressure protection PC31 Low-pressure protection PH09 Anti-cold-air in heating PH90 Evaporator too hot protection PH91 Evaporator too cold protection LC01 Frequency limited by the outdoor coil temperature (T3) LC02 Frequency limited by the discharge temperature (TP) LC03 Frequency limited by current LC05 Frequency limited by voltage LC06 Frequency limited by the IPM temperature LH00 Frequency limited by the indoor coil temperature (T2) LH07 Frequency limited by the remote control nA No fault
Inventor U6RSL multi split (Midea-built)
- U6RSL multi
- U5MRSL multi
How to read codes on this unit
Indoor units show the indoor codes on their display. Units without a display flash the lamps instead: the operation lamp blinks a number of times, and the timer lamp is off, on or flashing (2 Hz). Outdoor 7-segment display: --= standby; a number = running frequency in Hz;dF= defrost;PH= pre-heat;RO= oil return;LC= low-ambient cooling;FC= forced cooling;E6= 3 PFC trips within 15 min;CE= auto-correction running. Anything else is an error code.Outdoor codes clear at least 30 s after the fault has gone, except E2andE3on the (2)-18.Point check (SW1): press SW1 repeatedly while the unit runs to step through the readings. On the (3)-27, press 49 shows why the unit stopped; on the others, press 45 shows the last error code ( 00= none) and press 52 the reason for the last shutdown.Wiring / piping auto-correction: hold the outdoor check switch for 5 s until CEshows; it takes 5–10 min.The U5MRSL (4-port) and the Midea M2OH / M3OE outdoor units are covered only by inference from this manual: the U5MRSL is the same Inventor multi range without its own service manual; for the M2OH / M3OE the hints are the shared GMCC compressor and the Midea outdoor model names in this manual. Check the 7-segment display on the unit before relying on this table for them.
Indoor unit codes
E0 Indoor EEPROM error E1 Indoor ↔ outdoor communication error E3 Indoor fan speed out of range E4 Room sensor T1 open or short E5 Indoor coil sensor T2 open or short EC Refrigerant leak detected EE Water-level alarm F0 Over-current protection F1 Outdoor ambient sensor T4 open or short F2 Outdoor coil sensor T3 open or short F3 Discharge sensor T5 open or short F4 Outdoor EEPROM error F5 Outdoor fan speed out of range F6 Pipe sensor T2B open or short FA Communication error between the two chips on the indoor PCB P0 IPM module protection P1 Over- or under-voltage protection P3 Ambient temperature too low P4 Inverter compressor drive error -- Indoor units in conflicting modes P6 Low-pressure protection
Outdoor display codes: U6RSL(2)-18
E0 Outdoor EEPROM error E2 Indoor ↔ outdoor communication error E3 IPM board ↔ main board communication error E4 Outdoor sensor T3, T4 or T5 open or short F1 T2B sensor of room A missing or faulty F2 T2B sensor of room B missing or faulty F3 T2B sensor of room C missing or faulty F4 T2B sensor of room D missing or faulty F5 T2B sensor of room E missing or faulty E5 Voltage protection (low AC voltage or high DC bus voltage) E6 PFC protection E8 Outdoor fan speed or compressor speed error P0 Compressor top temperature protection P3 Compressor current protection P4 Discharge temperature protection (above 115 °C) P5 Condenser high-temperature protection (T3 above 65 °C) P6 IPM module protection E9 Wiring error with a 24k indoor unit LP Low outdoor ambient protection
Outdoor display codes: U6RSL(3)-27 and U6RSL(5)-42
EC51 Outdoor EEPROM error EL01 Indoor ↔ outdoor communication error PC40 IPM board ↔ main board communication error EC50 Outdoor sensor T3, T4 or T5 open or short EC52 Outdoor coil sensor T3 open or short EC53 Outdoor ambient sensor T4 open or short EC54 Discharge sensor T5 open or short EC56 T2B sensor of one room missing or faulty PC10 Low AC voltage protection PC11 High DC bus voltage protection PC12 High DC bus voltage or 341 MCE error PC0F PFC protection EC07 Outdoor fan speed out of range EC71 Outdoor fan over-current EC72 Outdoor fan phase loss PC02 Compressor top temperature protection PC08 Compressor current protection PC44 Compressor zero speed PC46 Compressor speed out of control PC49 Compressor over-current PC43 Compressor phase loss PC45 IR drive chip failure PC06 Discharge temperature protection (above 115 °C) PC0A Condenser high-temperature protection (T3 above 65 °C) PC00 IPM module protection PC30 High-pressure protection PC31 Low-pressure protection PC0L Low outdoor ambient protection