Inventor error codes

Display codes

Inventor E1

Indoor ↔ outdoor communication error

Inventor – Aria AR5 (AR5VI / AR5VO)

Ranges
  • Aria AR5
  • Indoor unit
  • Also shown as EL01
  • Lamps: run lamp blinks 2×, timer lamp off

Likely causes

Interconnect wiring, outdoor board supplies, a shorted load, EXV coil, PCB.

First checks

Check the wiring and terminals; measure DC volts between N (L2) and S: swinging between + and − = OK, always + → outdoor side, fixed or about 0 V → indoor side; check the 5 V and 12 V supplies; reactor ≈ 0 Ω.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.062022, ManualsLib page 99–100

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi
  • Lamps: run lamp blinks 2×, timer lamp off

Likely causes

Interconnect wiring, outdoor IPM board or main board, indoor PCB.

First checks

Do all indoor units show it? → measure the DC voltage between S and N: it should swing between + and − → check the LEDs on the IPM board and the main board → check the reactor; outdoor point check press 1 shows how many indoor units the outdoor unit sees.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31, 36–38

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Inventor error codes