Inventor error codes

Display codes

Inventor E2

Zero-crossing detection error

Inventor – Aria AR5 (AR5VI / AR5VO)

Ranges
  • Aria AR5
  • Indoor unit
  • Also shown as EH02
  • Lamps: run lamp blinks 3×, timer lamp off

Likely causes

Supply, indoor PCB.

First checks

Check the supply and its connections → replace the indoor PCB.

Note

Only on some models.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.062022, ManualsLib page 101

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

Indoor ↔ outdoor communication error

Likely causes

Interconnect wiring, IPM board or main board, indoor PCB.

First checks

Do all indoor units show it? → measure the DC voltage between S and N: it should swing between + and − → check the LEDs on the IPM board and the main board → check the reactor; point check press 1 shows how many indoor units the outdoor unit sees.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 36–38

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Inventor error codes