Inventor error codes

Display codes

Inventor E3

Indoor fan speed out of range

Inventor – Aria AR5 (AR5VI / AR5VO)

Ranges
  • Aria AR5
  • Indoor unit
  • Also shown as EH03
  • Lamps: run lamp blinks 4×, timer lamp off

Likely causes

Fan motor, its wiring, indoor PCB.

First checks

Turn the fan by hand (seized?) → measure at the motor connector: Vs 280–380 V, Vcc 14–17.5 V, Vsp 0–5.6 V, FG 14–17.5 V → replace the motor or the PCB.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.062022, ManualsLib page 102–103

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi
  • Lamps: run lamp blinks 4×, timer lamp off

Likely causes

Fan motor, indoor PCB.

First checks

Turn the fan by hand → check the voltages at the motor connector → replace the motor or the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

IPM board ↔ main board communication error

Likely causes

Signal wire, IPM board, main board.

First checks

Is any LED on the IPM board lit? → check the signal wire → replace the IPM board → replace the main board.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 45

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Inventor error codes