Inventor error codes

Display codes

Inventor E4

Room sensor T1 open or short

Inventor – Aria AR5 (AR5VI / AR5VO)

Ranges
  • Aria AR5
  • Indoor unit
  • Also shown as EH60
  • Lamps: run lamp blinks 5×, timer lamp off

Likely causes

Sensor, indoor PCB.

First checks

Check the connector; measure the sensor's resistance against its R-T table (10 kΩ at 25 °C) → out of range: replace the sensor, else the PCB.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.062022, ManualsLib page 105

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi
  • Lamps: run lamp blinks 5×, timer lamp off

Likely causes

Sensor, indoor PCB.

First checks

Measure the sensor's resistance against its R-T table → replace the sensor or the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

Outdoor sensor T3, T4 or T5 open or short

Likely causes

Sensor, its connector, outdoor PCB.

First checks

Check the connector → measure the sensor's resistance against its R-T table (T5: 5 kΩ at 90 °C) → replace the sensor or the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 33–34

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Inventor error codes