Inventor error codes

Display codes

Inventor E5

Indoor coil sensor T2 open or short

Inventor – Aria AR5 (AR5VI / AR5VO)

Ranges
  • Aria AR5
  • Indoor unit
  • Also shown as EH61
  • Lamps: run lamp blinks 6×, timer lamp off

Likely causes

Sensor, indoor PCB.

First checks

Check the connector; measure the sensor's resistance against its R-T table → out of range: replace the sensor, else the PCB.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.062022, ManualsLib page 105

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi
  • Lamps: run lamp blinks 6×, timer lamp off

Likely causes

Sensor, indoor PCB.

First checks

Measure the sensor's resistance against its R-T table → replace the sensor or the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

Voltage protection (low AC voltage or high DC bus voltage)

Likely causes

Supply, bridge rectifier, IPM board.

First checks

Measure L–N: 220–240 V → check that the DC voltage P–N is in range → check the bridge rectifier → the IPM board → the main board.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 46

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.