Inventor error codes

Display codes

Inventor EC56

Indoor coil outlet sensor T2B open or short (multi split)

Inventor – Leon (LHUVI / LEUVI)

Ranges
  • Leon
  • Outdoor unit

Likely causes

Sensor, its connector, outdoor PCB.

First checks

Check the connector; measure the sensor's resistance against its table → out of range: replace the sensor, else the PCB.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.072023, ManualsLib page 81–82

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

T2B sensor of one room missing or faulty

Likely causes

Sensor, its connector.

First checks

Check the connector → measure the sensor's resistance against its R-T table.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 32–33