Inventor error codes

Display codes

Inventor P4

Inverter compressor drive error

Inventor – Aria AR5 (AR5VI / AR5VO)

Ranges
  • Aria AR5
  • Outdoor unit
  • Also shown as PC04
  • Lamps: run lamp blinks 5×, timer lamp flashing

Likely causes

Compressor wiring, IPM, poor ventilation, compressor.

First checks

Check the compressor wiring → outdoor fan and ventilation → compressor windings → IPM continuity (P to U, V, W, N and U, V, W to N: several MΩ) → outdoor PCB.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.062022, ManualsLib page 113

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi
  • Lamps: run lamp blinks 5×, timer lamp flashing

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

Discharge temperature protection (above 115 °C)

Likely causes

Low refrigerant charge, discharge sensor.

First checks

Search for a leak and recharge → check the sensor's wiring and resistance → replace the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 51

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.