Inventor error codes

Display codes

Inventor PC00

IPM protection or IGBT over-current

Inventor – Leon (LHUVI / LEUVI)

Ranges
  • Leon
  • Outdoor unit

Likely causes

Compressor wiring, IPM, poor airflow, refrigerant circuit, compressor.

First checks

Check the U/V/W wiring → IPM diode test → outdoor fan and coil → compressor windings balanced? → valves and EEV → outdoor PCB, then the compressor.

Source: Inventor Wall Mounted Unit Service Manual V:1.0.072023, ManualsLib page 81–82

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

IPM module protection

Likely causes

Supply, wiring, compressor, outdoor fan, bridge rectifier, PFC.

First checks

Measure the DC voltage P–N → check the supply → the wiring between the main board and the IPM → the compressor leads → the IPM → the outdoor fan → the bridge rectifier → the reactor → the PFC → the compressor.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 53