Inventor error codes

Outdoor display codes: U6RSL(3)-27 and U6RSL(5)-42

Inventor PC12

High DC bus voltage or 341 MCE error

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

Likely causes

Supply, bridge rectifier, IPM board.

First checks

Measure L–N: 220–240 V → check that the DC voltage P–N is in range → check the bridge rectifier → the IPM board → the main board.

Note

This is the meaning in the U6RSL manual. Other Midea boards may use PC12 differently (e.g. for low DC bus voltage).

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 46

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Inventor error codes