Inventor error codes

Engineer-mode codes

Inventor PC46

Compressor speed out of control

Inventor – Leon (LHUVI / LEUVI)

Ranges
  • Leon
  • Outdoor unit

Source: Inventor Wall Mounted Unit Service Manual V:1.0.072023, ManualsLib page 86–87

Inventor U6RSL multi split (Midea-built)

Ranges
  • U6RSL multi
  • U5MRSL multi

Likely causes

Refrigerant system, outdoor ambient above 50 °C, poor ventilation, dirty outdoor coil, blocked pipe, main board.

First checks

Measure the input current → check the airflow and the outdoor coil → look for a blocked pipe → replace the main board.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 50