Midea error codes

Outdoor display codes: U6RSL(2)-18

Midea E2

Indoor ↔ outdoor communication error

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

Likely causes

Interconnect wiring, IPM board or main board, indoor PCB.

First checks

Do all indoor units show it? → measure the DC voltage between S and N: it should swing between + and − → check the LEDs on the IPM board and the main board → check the reactor; point check press 1 shows how many indoor units the outdoor unit sees.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 36–38

Midea – old 2-character codes (about 2017–2019)

Ranges
  • Oasis Plus 2018

Zero-crossing detection error

  • Indoor unit
  • Lamps: run lamp blinks 3×, timer lamp off

Likely causes

Supply, indoor PCB.

First checks

Check the supply and its connections → replace the indoor PCB.

Source: Midea Technical Support, New Error Code System – Typical Troubleshooting Cases (Dec 2019), slide 4

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes