Midea error codes

Codes on the indoor display

Midea EC56

Indoor coil outlet sensor T2B open or short (multi split)

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Outdoor unit

Likely causes

Sensor, its connector, outdoor PCB.

First checks

Check the connector → measure the sensor's resistance against its table → out of range: replace the sensor, else the outdoor PCB.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 68

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

T2B sensor of one room missing or faulty

Likely causes

Sensor, its connector.

First checks

Check the connector → measure the sensor's resistance against its R-T table.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 32–33

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes