Midea error codes

Codes on the indoor display

Midea EL01

Indoor ↔ outdoor communication error

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Indoor unit
  • Old Midea code: E1
  • Lamps: run lamp blinks 2×, timer lamp off

Likely causes

Interconnect wiring, outdoor PCB or IPM board supply, a shorted load, EEV coil, indoor PCB.

First checks

Power-cycle → check the wiring and terminals → measure DC volts between outdoor terminals 2 (S) and 3 (N): normally the reading swings about ±25 V; always + → outdoor side, fixed → indoor side; check the 5 V and 12 V supplies; unplug the loads one by one.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 60–61

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

Likely causes

Interconnect wiring, IPM board or main board, indoor PCB.

First checks

Do all indoor units show it? → measure the DC voltage between S and N: it should swing between + and − → check the LEDs on the IPM board and the main board → check the reactor; point check press 1 shows how many indoor units the outdoor unit sees.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 36–38