Midea error codes

Indoor unit codes

Midea P1

Over- or under-voltage protection

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi
  • Lamps: run lamp blinks 2×, timer lamp flashing

Likely causes

Supply, bridge rectifier, IPM board.

First checks

Measure L–N: 220–240 V → check that the DC voltage P–N is in range → check the bridge rectifier → the IPM board → the main board.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31, 46

Midea – old 2-character codes (about 2017–2019)

Ranges
  • Oasis Plus 2018

Over- or under-voltage

  • Outdoor unit
  • Lamps: run lamp blinks 2×, timer lamp flashing

Likely causes

Supply, reactor, IPM board.

First checks

Check the supply; DC voltage P–N ≈ 310 V at standby (220–400 V while starting); check the reactor.

Source: Oasis Plus 3D Inverter Series 2018 Service Manual, R32, p. 71–72

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes