Midea error codes

Indoor unit codes

Midea P6

Low-pressure protection

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi
  • Lamps: run lamp blinks 7×, timer lamp flashing

Likely causes

Closed service valve, low refrigerant charge, low-pressure switch.

First checks

Check that the service valves are open → check the charge → check the low-pressure switch.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 31

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

IPM module protection

Likely causes

Supply, wiring, compressor, outdoor fan, bridge rectifier, PFC.

First checks

Measure the DC voltage P–N → check the supply → the wiring between the main board and the IPM → the compressor leads → the IPM → the outdoor fan → the bridge rectifier → the reactor → the PFC → the compressor.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 53