Midea error codes

Codes on the indoor display

Midea PC01

Over- or under-voltage (DC bus P–N out of range)

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Outdoor unit
  • Old Midea code: P1
  • Lamps: run lamp blinks 2×, timer lamp flashing

Likely causes

Supply, wiring, reactor, IPM board.

First checks

Check the supply → DC voltage P–N at standby about 310, 340 or 380 V, while starting 220–400 V → reactor about 0 Ω → IPM board or outdoor PCB.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 73

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes