Midea error codes

Codes on the indoor display

Midea PC02

Compressor top or IPM over-temperature

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Outdoor unit
  • Old Midea code: P2
  • Lamps: run lamp blinks 3×, timer lamp flashing

Likely causes

Blocked airflow, low charge or a blockage, poor heatsink contact, overload protector (OLP).

First checks

Check the airflow → wait 10 min → compressor top above 90 °C: check the refrigerant circuit; tighten the heatsink screws and renew the thermal grease; the OLP should read 0 Ω.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 74

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

Compressor top temperature protection

Likely causes

Poor airflow, refrigerant circuit, compressor overload protector (OLP).

First checks

Wait 10 min → is the top of the compressor above 90 °C? → the OLP should read 0 Ω → check the refrigerant circuit → replace the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 54

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes