Midea error codes

Codes on the indoor display

Midea PC04

Inverter compressor drive error

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Outdoor unit
  • Old Midea code: P4
  • Lamps: run lamp blinks 5×, timer lamp flashing

Likely causes

Compressor wiring, IPM, poor airflow, refrigerant circuit, compressor.

First checks

Check the U / V / W compressor wiring → diode-test the IPM → check the outdoor fan and coil → are the compressor windings balanced? → check the valves and EEV → outdoor PCB, then the compressor; read the sub-code (PC40 … PC49).

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 71

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes