Midea error codes

Extended list (engineering mode)

Midea PC06

Discharge pipe high temperature

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Outdoor unit

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 50–51

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

Discharge temperature protection (above 115 °C)

Likely causes

Low refrigerant charge, discharge sensor.

First checks

Search for a leak and recharge → check the sensor's wiring and resistance → replace the PCB.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 51

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Midea error codes