Midea error codes

Codes on the indoor display

Midea PC08

Over-current protection

Midea – new 4-character codes (current R32 units)

Ranges
  • Oasis Plus
  • All Easy Pro
  • Breezeless E
  • Breezeless+
  • Xtreme Save / Xtreme Save Pro
  • MSAG
  • Solstice
  • Solunar
  • M2OH / M3OE multi
  • Outdoor unit
  • Old Midea code: F0
  • Lamps: run lamp blinks 1×, timer lamp flashing

Likely causes

Supply, blockage in the system, compressor, reactor.

First checks

Check the supply → look for a blockage in the system → measure the compressor windings → check the reactor → outdoor PCB.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 50

Inventor U6RSL multi split (Midea-built)

Ranges
  • M2OH / M3OE multi

Compressor current protection

Likely causes

Refrigerant system, outdoor ambient above 50 °C, poor ventilation, dirty outdoor coil, blocked pipe, main board.

First checks

Measure the input current → check the airflow and the outdoor coil → look for a blocked pipe → replace the main board.

Source: Inventor Multi Split Unit Service Manual V:1.0.062022, p. 50