Mitsubishi Electric error codes

Indoor lamp, while the fault is live

Mitsubishi Electric blinks continuously

Miswiring or serial signal error

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN

Likely causes

Interconnect miswiring; no serial signal from the outdoor unit for 6 min; the indoor unit was once run on an MXZ multi outdoor unit that is not a low-standby type.

First checks

Follow the miswiring and serial signal check: 230 V on S1–S2 → voltage on S2–S3 → indoor or outdoor board; if the indoor unit was used on an MXZ before, clear the fault memory.

Note

The lamp blinks 0.5 s on, 0.5 s off without stopping.

Source: Mitsubishi Electric service manual OBH932 (MSZ-AY, Dec 2022), p. 35