Mitsubishi Electric error codes

Indoor lamp in recall mode: outdoor faults

Mitsubishi Electric 14 blinks

Stop valve closed

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN
  • Outdoor unit

First checks

Open the stop valve.

Note

Detected from the compressor current. 14 blinks can also mean a 4-way valve or pipe temperature error.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN

4-way valve or pipe temperature error

  • Outdoor unit

Likely causes

The 4-way valve does not switch; abnormal indoor coil thermistor reading.

First checks

Check the R.V. coil (230 V on CN721, in HEAT only) → check the inverter board.

Note

14 blinks can also mean a closed stop valve.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42