Mitsubishi Electric error codes

Indoor lamp in recall mode: outdoor faults

Mitsubishi Electric 16 blinks

Outdoor refrigerant system abnormality

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN
  • Outdoor unit

Likely causes

Closed valve or air in the circuit (judged from temperatures and current), or a refrigerant charge down to 60 % or less.

First checks

Was the unit stopped during pump-down? → close the valve, switch the power off and do not restart; was it started with a closed valve? → open the valve and restart; otherwise the charge may be down to 60 % or less → find the leak.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.