Mitsubishi Electric error codes

Indoor lamp in recall mode: outdoor faults

Mitsubishi Electric 4 blinks

Over-current into power module IC700

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN
  • Outdoor unit
  • detailed recall only

Likely causes

A large current into the power module.

First checks

Reconnect the compressor connector → check the inverter and the compressor → check the stop valve.

Note

4 blinks in the detailed recall can also mean a compressor synchronous abnormality.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN

Compressor synchronous abnormality (start-up failure)

  • Outdoor unit
  • detailed recall only

Likely causes

A distorted compressor current waveform.

First checks

Reconnect the connectors → check the inverter and the compressor.

Note

4 blinks in the detailed recall can also mean over-current into power module IC700.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Mitsubishi Electric error codes