Mitsubishi Electric error codes

Indoor lamp in recall mode: outdoor faults

Mitsubishi Electric 9 blinks

Outdoor nonvolatile memory error

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN
  • Outdoor unit

Likely causes

The memory data can't be read.

First checks

Replace the inverter board.

Note

Shown in the normal recall. In the detailed recall, 9 blinks can also mean a power module IC700 fault.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42

Mitsubishi Electric MSZ-AY / HR / EF / LN – lamp and LED codes

Ranges
  • MSZ-AY / MUZ-AY
  • MSZ-HR / MUZ-HR
  • MSZ-EF / MUZ-EF
  • MSZ-LN / MUZ-LN

Power module IC700 fault

  • Outdoor unit
  • detailed recall only

Likely causes

Short in the module's output or in a compressor winding.

First checks

Check the inverter and the compressor.

Note

9 blinks in the normal recall means an outdoor nonvolatile memory error.

Source: Mitsubishi Electric service manual OBH931 Rev B (MUZ-AY, Dec 2024), p. 41–42