Error codes by brand

Samsung error codes

Samsung wall units show three-digit codes. Current models show them with a C (C101); older documents write the same code with an E (E101). Free Joint Multi outdoor units show their codes on the outdoor board's display.

Samsung – wall splits (RAC), 3-digit codes

Ranges
  • AR50F / AR60F / AR70F (WindFree)

Codes of Samsung wall splits (RAC): the short installer list from the AR50F / AR60F / AR70F installation manual (2025), plus the full list from a 2018 service manual of the same platform. Each code is a letter and three digits, e.g. C101 or E101.

How to read codes on this unit
  • Indoor display: current models show C + the number, e.g. C101, C554. Older documents and the 2018 service manual write E (E101). It is the same code. Samsung's support page shows the code split in two on the display, e.g. C1 21 for C121.
  • E2xx on the indoor unit: an outdoor error is being reported. Read the outdoor code.
  • Outdoor board: the outdoor code shows on the board's 7-segment display and LEDs.
  • Test mode: hold the indoor unit's ON/OFF button for 5 s → forced cooling, turbo fan, anti-freeze protection off.
  • Smart Install (installation check): in standby hold Power + Dry Comfort + Max for 5 s. The display counts 0–99; it takes 7–13 min and ends with a chime or with a code from the installer list.

Installer list (AR50F / AR60F / AR70F installation manual, 2025)

The models' own manual. It gives a short installer action for each code.

Full code list (2018 service manual)

From the 2018 service manual of a different model on the same platform (AR09–24RXPXBWKNEU). Current models show these codes with C instead of E, e.g. E101 = C101.

Samsung – Free Joint Multi outdoor units (AJ…TXJ…KG)

Ranges
  • Free Joint Multi (FJM)

Codes shown on the outdoor unit of Samsung Free Joint Multi (FJM) R32 multi splits, from the AJ…TXJ…KG installation manual. Where fault-finding steps are given, they come from the 2020 service manual of the North-American R410A version of the same range.

How to read codes on this unit
  • The code shows on the two-digit segment displays of the outdoor main PCB (MAIN-OUT).
  • At first power-up the display shows E199 and the number of indoor units until the pipe check has been run. Press K1 once to run it (3–5 min).
  • K1 presses: 1 = pipe check, 2 = cooling test run, 3 = heating test run, 4 = pump-down, 5 = end. K3 = reset.
  • K4 = view mode. Each press shows the next item: compressor Hz, target Hz, EEV 0–4, fan rpm, discharge temperature, OLP temperature, condenser temperature, outdoor temperature, current, target discharge temperature, total indoor capacity, safety state.
  • The indoor units report the Samsung indoor codes (E101, E121, E122, E123, E154, E162, E163) on their display or LEDs. A wired controller shows them via its Test button.

Outdoor unit codes

From the installation manual's error list. Fault-finding steps come from the North-American R410A service manual of the same range.

No codes yet for: AR40H