Vivax E1

Indoor ↔ outdoor communication error

Midea – old 2-character codes (about 2017–2019)

Ranges
  • AENI (N+)
  • AEHI+ (H+)
  • AEYIs (Y)
  • Indoor unit
  • Lamps: run lamp blinks 2×, timer lamp off

Likely causes

Interconnect wiring, reactor, outdoor PCB, indoor PCB.

First checks

Check the wiring and terminals; measure DC volts between outdoor terminals 2 and 3: the reading should swing between + and −; always + → outdoor side, fixed → indoor side; reactor ≈ 0 Ω.

Note

Shown when the indoor unit gets no reply for 150 s, four times while running.

Source: Oasis Plus 3D Inverter Series 2018 Service Manual, R32, p. 62–63