Vivax error codes

Codes in the 2018 service manual

Vivax E5

Indoor coil sensor T2 open or short

Midea – old 2-character codes (about 2017–2019)

Ranges
  • AENI (N+)
  • AEHI+ (H+)
  • AEYIs (Y)
  • Indoor unit
  • Lamps: run lamp blinks 6×, timer lamp off

Likely causes

Sensor, its connector, indoor PCB.

First checks

Check the connector; measure the sensor's resistance against its table; sampling voltage below 0.06 V or above 4.94 V = fault → sensor, else PCB.

Source: Oasis Plus 3D Inverter Series 2018 Service Manual, R32, p. 67

Vivax T Design (ACP-…LCTI)

Ranges
  • T Design

Indoor fan motor fault

  • Indoor unit

Source: Vivax owner's manual ACP-xxCHxxLCTI R32 Black, p. 34

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Vivax error codes