Vivax PC02

Compressor top or IPM over-temperature

Midea – new 4-character codes (current R32 units)

Ranges
  • AERI PRO / AEMI PRO / AEQI PRO / AEGI PRO / AEXI PRO / AEFI PRO
  • AENI (N+)
  • AEHI+ (H+)
  • COFM multi
  • Outdoor unit
  • Old Midea code: P2
  • Lamps: run lamp blinks 3×, timer lamp flashing

Likely causes

Blocked airflow, low charge or a blockage, poor heatsink contact, overload protector (OLP).

First checks

Check the airflow → wait 10 min → compressor top above 90 °C: check the refrigerant circuit; tighten the heatsink screws and renew the thermal grease; the OLP should read 0 Ω.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 74

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Vivax error codes