How it works
One fault, from the code to the record.
This is how you work through a fault with ClimaToolkit: on site on your phone, the record later at the desk too. Each step leads to the next.
1Step 1 of 4 · Code
Start with the code on the display.
Type the code or a few words, pick the brand or type the model number from the nameplate. You get what the code means, and the likely causes and first checks where the service manual gives them.
- Brands: Midea, Inventor, Samsung, Mitsubishi Electric, Vivax.
- The same code in different ranges: a result for each range.
- No display? Search by the blinking lamps.
No account needed.
Next: ReadingsIndoor ↔ outdoor communication error
Likely causes
- Interconnect wiring
- Reactor
- Outdoor PCB
- Indoor PCB
First checks
- The wiring and terminals.
- DC volts between outdoor terminals 2 and 3: the reading should swing between + and −.
- Reactor ≈ 0 Ω.
2Step 2 of 4 · Readings
Measure, and let the numbers be judged.
Superheat, subcooling, P-T and the other calculators take altitude and gauge zero into account. Superheat and subcooling also tell you in words whether they are normal.
- For blends: the dew point for superheat, the bubble point for subcooling.
- Set the refrigerant, altitude and gauge zero once for all calculators.
- Low side in blue, high side in red — like on a gauge set.
No account needed.
Next: Diagnose3Step 3 of 4 · Diagnose
When it isn’t clear why, open Diagnose.
Symptoms, error codes and readings in one place. It compares each reading with the normal range and tells you what to check first.
- How to start the test run, per maker.
- Save the result to the unit’s history.
- Ranked causes and maker charts in Pro.
A free sign-in is enough.
Next: RecordReadings
- Superheat6.8 Knormal 0–5 K
high - Subcooling1.2 Knormal 2.5–10 K
low - Evaporating2.5 °Cnormal 2–13 °C
normal
Likely causes Pro
4Step 4 of 4 · Record
Save the work to the unit.
Log a diagnosis, service, repair or leak check in the unit’s history. See the leak-check dates by t CO₂-eq in one place.
- The yearly F-gas report.
- PDF service report in Pro.
- Optional customer details on the unit, printed on its PDFs.
Part of Pro.
During the beta, Pro is free for everyone who signs in.
| Unit | Refrigerant | Charge | t CO₂-eq | Leak checks |
|---|---|---|---|---|
| Mitsubishi Electric 14 kWA-01 | R410A | 4.20 kg | 8.77 | every 12 months |
| Samsung FJM 10 kWA-02 | R410A | 3.00 kg | 6.26 | every 12 months |
| Midea Oasis 3.5 kWB-01 | R32 | 0.85 kg | 0.57 | not required |
On site and at the desk
One account on your phone and computer.
- Works in the browser, nothing to install. iPhone app coming soon.
- Calculators and error codes work without an account.
- Units and records are in your account: the same on your phone and computer.