Vivax error codes

Codes on the indoor display

Vivax PC03

High or low pressure protection (units with pressure switches)

Midea – new 4-character codes (current R32 units)

Ranges
  • AERI PRO / AEMI PRO / AEQI PRO / AEGI PRO / AEXI PRO / AEFI PRO
  • AENI (N+)
  • AEHI+ (H+)
  • COFM multi
  • Outdoor unit

Likely causes

High pressure: dirty coil, fan, overcharge, air in the system. Low pressure: closed valve, indoor fan, low charge.

First checks

Check the switch wiring; a closed switch reads about 0 Ω; the high-pressure switch opens above 4.4 MPa, the low-pressure switch below 0.13 MPa → then check the airflow, valves and charge.

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 75–77

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.

Open in the appAll Vivax error codes