Vivax error codes

Codes on the indoor display

Vivax PC04

Inverter compressor drive error

Midea – new 4-character codes (current R32 units)

Ranges
  • AERI PRO / AEMI PRO / AEQI PRO / AEGI PRO / AEXI PRO / AEFI PRO
  • AENI (N+)
  • AEHI+ (H+)
  • COFM multi
  • Outdoor unit
  • Old Midea code: P4
  • Lamps: run lamp blinks 5×, timer lamp flashing

Likely causes

Compressor wiring, IPM, poor airflow, refrigerant circuit, compressor.

First checks

Check the U / V / W compressor wiring → diode-test the IPM → check the outdoor fan and coil → are the compressor windings balanced? → check the valves and EEV → outdoor PCB, then the compressor; read the sub-code (PC40 … PC49).

Source: Midea Service Manual EX R32 3D Inverter, SM_EX(GA)_R32_3D INV_EU_NA1_2510 (Oct 2025), p. 71

In the app you also find codes by the model number on the nameplate, and Diagnose judges your readings.